Product Description
Walk in test chamber is applied to Patchwork type chamber, with the feature of nice looking outlook, scientific design for pipe and duct, all in one touch screen control panel and programmable logic controller can satisfy most needs of all kinds of clients.
General Specification
chamber with internal air circulation, and all the heaters and cooling coil located behind/below the false sheet of the chamber and outside the working space
the conditioning with air circulation to maintain uniform temperatur
interior have provision for arranging stainless steel
insulation is asbestos-free csc-free, with low thermal conductivity, polyrthene pu foam
cooling system
cascade type, refrigeration system with hermetically sealed refrigeration
cycles with environment and ozone friendly and chloride free refrigeration
lockable front opening, with double door latch easy to open
with silicon gasket for perfect sealing
viewing interlock is sealed to avoid leakage and provided with heating provision to prevent condensation
inernallight on viewing windows with external control
the temperature measuring and control system adopts microprocessor system and provided with touch panel for monitoring and digital display:
supplied with support software
software is capable to visualize and graphical anallyse the measured & recorded value.
graphical representation and digital display and control of set and actual values
digital input and display of temperature in degree centigrade
fault diagnosis system
120 stroage of programmes
have adjustable safety cut-out against high and low temperature
facility to programme temperature measuring using sensor pt100
standard rs -232 interface for pc connectivity
rs-232 cable for pc connectivity along with pc connectivity software
each port hole provided with silicon sealing bunker (plug)
all power connectors, protection devices power control logic built in the control panel integrated to the chamber
all electrical cables tagged with id number
all electrical function circuit equipped with its own safety device that shuts down the relevant circuit or the entire test chamber if a faulty develops
all electrical systems comply with recognized technical regulation as well as with the accident prevention regulations.
protective feature to be provided as follows:
over load trip & earth leakage trip for complete chamber
over load trip for compressors, heaters and motors
over temperature cut-off for compressors
heater be cut off, if air circulation blowers are off
detailed operating & maintanance manual
operational instruction
complete list parts
preventive maintenance procedure
trouble shooting measures
electrical circuit diagrams
Testing Sample
solor panels, size 2mh * 1mw * 1md, size 2mh * 1mw * 1md
Humidity Range
Product Peremeters
SR NO |
SPECIFICATION |
HD-E705-8 |
1 |
TEMPERATURE RANGE |
-50C TO +100C |
2 |
HUMIDITY RANGE |
40% TO 98% RH |
3 |
DIMENSION (INTERNAL) (W X D X H) |
1500 X 1500 X 3000 MM |
4 |
DIMENSION (EXTERNAL) (W X D X H) |
2850 X 1700 X 3200 MM |
5 |
RAMP |
VARIABLE, TEMP. 0~5C / MIN & HUMIDITY 0~5%/MIN IN AVERAGE, NO LOAD |
6 |
ACCURACY |
TEMP. ±1C, HUMIDITY ±2.5%RH |
7 |
INTERIOR WALLS |
STAINLESS STEEL 304 |
8 |
EXTERIOR WALLS |
COLD ROLLED STELL PLATE WITH BAKING FINISH |
9 |
TEMPERATURE & HUMIDITY MEASUREMENT AND CONTROLLER |
32 BIT CONTROL AND MONITORING SYSTEM. INTERFACE FACILITY WITH RS232 PROGRAMMABLE TEMP. HUMID. CONTROLLER |
10 |
VIEWING WINDOW |
MULTI PANE GLASS WINDOW SIZE |
11 |
PORT HOLES |
50 MM DIAMETER FOR WIRE ROUTING |
12 |
POWER SUPPLY REQUIREMENT |
THREE PHASE, AC380 V ± 10 %, 50 HZ |
13 |
SOUND PRESSURE LEVEL |
<72DB (A) |
14 |
CONDENSER COOLING |
WATER COOLED |
|
GENERAL TECHNICAL SPECIFICATION |
|
15 |
THERMAL CYCLIC CHAMBER |
|
15.1 |
CHAMBER WITH INTERNAL AIR CIRCULATION, AND ALL THE HEATERS AND COOLING COIL LOCATED BEHIND/BELOW THE FALSE SHEET OF THE CHAMBER AND OUTSIDE THE WORKING SPACE |
|
16 |
INTERIOR |
|
16.1 |
THE CONDITIONING WITH AIR CIRCULATION TO MAINTAIN UNIFORM TEMPERATUR |
|
16.2 |
INTERIOR HAVE PROVISION FOR ARRANGING STAINLESS STEEL |
|
17 |
INSULATION |
|
17.1 |
INSULATION IS ASBESTOS-FREE CSC-FREE, WITH LOW THERMAL CONDUCTIVITY, POLYRTHENE PU FOAM |
|
18 |
COOLING SYSTEM |
|
18.1 |
CASCADE TYPE, REFRIGERATION SYSTEM WITH HERMETICALLY SEALED REFRIGERATION CYCLES WITH ENVIRONMENT AND OZONE FRIENDLY AND CHLORIDE FREE REFRIGERATION |
|
19 |
DOOR |
|
19.1 |
LOCKABLE FRONT OPENING, WITH DOUBLE DOOR LATCH EASY TO OPEN |
|
19.2 |
WITH SILICON GASKET FOR PERFECT SEALING |
|
20 |
VIEWING WINDOW |
|
20.1 |
VIEWING INTERLOCK IS SEALED TO AVOID LEAKAGE AND PROVIDED WITH HEATING PROVISION TO PREVENT CONDENSATION |
|
21 |
ILLUMINATION |
|
21.1 |
INERNALLIGHT ON VIEWING WINDOWS WITH EXTERNAL CONTROL |
|
22 |
TEMPERATURE MEASURING AND CONTROL SYSTEM |
|
22.1 |
THE TEMPERATURE MEASURING AND CONTROL SYSTEM ADOPTS MICROPROCESSOR SYSTEM AND PROVIDED WITH TOUCH PANEL FOR MONITORING AND DIGITAL DISPLAY: SUPPLIED WITH SUPPORT SOFTWARE SOFTWARE IS CAPABLE TO VISUALIZE AND GRAPHICAL ANALLYSE THE MEASURED & RECORDED VALUE. |
|
A. |
GRAPHICAL REPRESENTATION AND DIGITAL DISPLAY AND CONTROL OF SET AND ACTUAL VALUES |
|
B. |
DIGITAL INPUT AND DISPLAY OF TEMPERATURE IN DEGREE CENTIGRADE |
|
C. |
FAULT DIAGNOSIS SYSTEM |
|
D. |
120 STROAGE OF PROGRAMMES |
|
22.2 |
HAVE ADJUSTABLE SAFETY CUT-OUT AGAINST HIGH AND LOW TEMPERATURE |
|
22.3 |
FACILITY TO PROGRAMME TEMPERATURE MEASURING USING SENSOR PT100 |
|
23 |
RECORDER & PC CONNECTIVITY |
|
23.1 |
STANDARD RS -232 INTERFACE FOR PC CONNECTIVITY |
|
23.2 |
RS-232 CABLE FOR PC CONNECTIVITY ALONG WITH PC CONNECTIVITY SOFTWARE |
|
24 |
PORT HOLES |
|
24.1 |
EACH PORT HOLE PROVIDED WITH SILICON SEALING BUNKER (PLUG) |
|
25 |
ELECTRICAL PANEL |
|
25.1 |
ALL POWER CONNECTORS, PROTECTION DEVICES POWER CONTROL LOGIC BUILT IN THE CONTROL PANEL INTEGRATED TO THE CHAMBER |
|
25.2 |
ALL ELECTRICAL CABLES TAGGED WITH ID NUMBER |
|
25.3 |
ALL ELECTRICAL FUNCTION CIRCUIT EQUIPPED WITH ITS OWN SAFETY DEVICE THAT SHUTS DOWN THE RELEVANT CIRCUIT OR THE ENTIRE TEST CHAMBER IF A FAULTY DEVELOPS |
|
25.4 |
ALL ELECTRICAL SYSTEMS COMPLY WITH RECOGNIZED TECHNICAL REGULATION AS WELL AS WITH THE ACCIDENT PREVENTION REGULATIONS. |
|
26 |
STANDARD PROTECTION |
|
26.1 |
PROTECTIVE FEATURE TO BE PROVIDED AS FOLLOWS: |
|
A. |
OVER LOAD TRIP & EARTH LEAKAGE TRIP FOR COMPLETE CHAMBER |
|
B. |
OVER LOAD TRIP FOR COMPRESSORS, HEATERS AND MOTORS |
|
C. |
OVER TEMPERATURE CUT-OFF FOR COMPRESSORS |
|
D. |
HEATER BE CUT OFF, IF AIR CIRCULATION BLOWERS ARE OFF |
|
27 |
OPERATING SYSTEM |
|
27.1 |
DETAILED OPERATING & MAINTANANCE MANUAL |
|
A. |
OPERATIONAL INSTRUCTION |
|
B. |
COMPLETE LIST PARTS |
|
C. |
PREVENTIVE MAINTENANCE PROCEDURE |
|
D. |
TROUBLE SHOOTING MEASURES |
|
E. |
ELECTRICAL CIRCUIT DIAGRAMS |
|
28 |
TESTING SAMPLE |
|
28.1 |
SOLOR PANELS, SIZE 2MH * 1MW * 1MD, SIZE 2MH * 1MW * 1MD |
Product number | HD-E705-8 | Brand | Haida Equipment |
---|---|---|---|
price | unit | USD | |
Minimum order quantity | 1 | Supply Capacity | 150 Set/Sets per Month |
payment method | Certification | ISO,CE | |
Place of origin | Guangdong, China | Packing details | Each set protected by resin fiber and PP film, then put into Strong wooden case with operation manual and vedio inside. |