Item | Specification |
Internal chamber dimension (W*D*H) | 1000*1000*1000mm |
External chamber dimension(W*D*H) | 1200*3000*3800mm approx. |
Temperature range | -40 ℃~ 150℃ |
Temperature fluctuation | ±0.5℃ |
Temperature uniformity | 2℃ |
Cooling speed(temp. Range: 85C~-40C) | 5℃/min in average; without loading |
Heating speed(temp. Range: -40C~85C) | 5℃/min in average; without loading |
Humidity range |
10~98%RH (please refer to the below humidity curve)![]() |
Humidity fluctuation | ±3%RH |
Internal chamber material | SUS#304 stainless steel, mirror finished |
External chamber material | Stainless steel with paint spray |
Cooling method | Water-cooled |
Controller |
Programmable control temperature and humidity Can set different parameter for cyclic test |
Insulation material | 50mm high density rigid Polyurethane foam |
Heater |
Explosion-proof type SUS#304 stainless steel fins radiator pipe heater |
Compressor | German Bock compressor |
Refrigerant | Environmental friendly refrigerant R449A/R23 |
Temperature sensor | PT-100 dry and wet bulb sensor |
Observation window | Tempered glass |
Testing hole | 2 units with diameter 100mm, for cable routing |
Sample tray | SUS#304 stainless steel, 2pcs |
Safety protection device |
Protection for leakage Over-temperature Compressor over-voltage and overload Heater short circuit |
Vibration Shaker | |
Max. Sine Force | 3200Kg.f peak |
Max. Random Force | 3200Kg.f r.ms |
Max. Shock Force | 6400Kg.f peak |
Frequency Range | 2~3000Hz |
Displacement (p-p) | 51 mm |
Max. Velocity | 2m/s |
Max. Table Acceleration | 100g (without loading) |
Armature Diameter | 335mm |
Effective Armature Mass | 30kg |
HE/ST screw dimension | 17×M10 |
Max. Load Capacity | 300kg |
Magnetic Leakage | <10gauss |
Axial Vibration Isolation Frequency | <2.5Hz |
Power | Three-phase, 380V, 50Hz |
Machine dimension | 845mm*790mm*840mm; without expander table |
Vibration controller system | |
Controller Hardware |
No of input channels: 02 analogue channels ADC: 24-bit Resolution No of output channels: 01 DAC: 24-bit Resolution USB 2.0 communication port |
Controller Software Modules |
Random Vibration (1-5000Hz), Sweep Sine Vibration (1-5000Hz), Classical Shock, Resonance Search, Track and Dwell and Self Calibration |
Other accessory |
Test Computer: LENOVO M4500 Printer: HP 1020plus |
Customer Responsibilities |
Installing all utilities where required, including connecting utilities to the equipment Installation/rigging of equipment Completing any necessary building alterations including roof penetrations Customers responsible for any permits required by - local/state government |
Expander | |
Expander Size | 600*600mm |
Material | Aluminum alloy with hard anodized surface |
Max. Work Frequency |
Sine: 1000Hz Random: 2000Hz |
Weigh | 32kg |
Slip Table | |
Table Size | 600*600mm |
Material | Aluminum alloy with hard anodized surface |
Max. Work Frequency |
Sine: 1000Hz Random: 2000Hz |
Weight | 35kg |
Note: 1. High pressure oil-film bearing is used for better uniformity. |
Power Amplifier | |
Max. Output Power | 32kVA |
Frequency response | >65 dB |
Output Voltage | 120V |
Conversion Efficiency | >90% |
Blower | |
Power | 15 |
Air volume | 0.66 |
Wind pressure | 0.075kgf/cm2 |
Air horse diameter | 200 |
SAFETY EQUIPMENT | SPECIFICATION |
Status indicator |
The tower light has 3 signal levels (white, green, and red) to quickly alert the operator of any abnormal conditions |
Electrical door lock |
The test space door is locked via an electrical door lock during automatic and manual tests. In automatic mode the complete testing system can be switched off during a program interruption, in order to allow the unlocking of the test space door |
Reversible pressure release flap |
This device is installed on the top of chamber |
Mechanical door lock |
Except reversible pressure release flap, two fasteners which mechanically hold the door closed are attached to the test space door |
Sealing plug and retaining clamp |
One 50mm or 100mm diameter cable port on left with flexible silicone plug |
Fire detection via CO gas measuring or temperature sensor |
The system is equipped with a control unit, an alarm panel, an emergency button, a thermostat with dedicated temperature probe and a system with a CO2 cylinder. The CO2 discharge is activated by exceeding a temperature threshold (settable by the user) measured by a dedicated PT100 or by exceeding the CO2 threshold inside the chamber The detection system, provided with its own power supply, activates the CO2 in the chamber. The CO2 bottle is empty |
Flushing device with N2 or with CO2 |
Monitors the gases in the chamber in all operating conditions |
Product number | HD-E809 | Brand | Haida |
---|---|---|---|
price | unit | Set | |
Minimum order quantity | 1 | Supply Capacity | 20 sets/Month |
payment method | L/C , T/T , D/A , D/P , Western Union , MoneyGram ,ect. | Certification | CE,ISO |
Place of origin | Guangdong, China | Packing details | Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside. |